Clinical Efficacy and Safety of Ranibizumab Versus Dexamethasone for Central Retinal Vein Occlusion (COMRADE C): A European Label Study

Jan 5, 2017 by in OPHTHALMOLOGY Comments Off on Clinical Efficacy and Safety of Ranibizumab Versus Dexamethasone for Central Retinal Vein Occlusion (COMRADE C): A European Label Study

We would like to address several challenges arising from the interesting study by Hoerauf and associates, which can be specifically summarized as follows: We do not agree with the assertion…

read more

Increased Choroidal Vascularity in Central Serous Chorioretinopathy Quantified Using Swept-Source Optical Coherence Tomography

Jan 5, 2017 by in OPHTHALMOLOGY Comments Off on Increased Choroidal Vascularity in Central Serous Chorioretinopathy Quantified Using Swept-Source Optical Coherence Tomography

Purpose To investigate the choroidal vascular structural changes in eyes with central serous chorioretinopathy (CSC) by using swept-source optical coherence tomography (SS-OCT). Design Prospective cross-sectional study. Methods We prospectively examined…

read more

Optical Coherence Tomography Angiography: A Useful Tool for Diagnosis of Treatment-Naïve Quiescent Choroidal Neovascularization

Jan 5, 2017 by in OPHTHALMOLOGY Comments Off on Optical Coherence Tomography Angiography: A Useful Tool for Diagnosis of Treatment-Naïve Quiescent Choroidal Neovascularization

Purpose To describe the optical coherence tomography angiography (OCT-A) features of treatment-naïve quiescent choroidal neovascularization (CNV) secondary to age-related macular degeneration, and to estimate the detection rate for neovascularization by…

read more

Determination and Validation of Thresholds of Anterior Chamber Parameters by Dedicated Anterior Segment Optical Coherence Tomography

Jan 5, 2017 by in OPHTHALMOLOGY Comments Off on Determination and Validation of Thresholds of Anterior Chamber Parameters by Dedicated Anterior Segment Optical Coherence Tomography

Purpose To determine and validate thresholds of anterior chamber angle (ACA) parameters in discriminating open- vs narrow-angle eyes using images from dedicated anterior segment optical coherence tomography (DASOCT). Design Reliability…

read more

Diagnostic Performance of a Novel Three-Dimensional Neuroretinal Rim Parameter for Glaucoma Using High-Density Volume Scans

Jan 5, 2017 by in OPHTHALMOLOGY Comments Off on Diagnostic Performance of a Novel Three-Dimensional Neuroretinal Rim Parameter for Glaucoma Using High-Density Volume Scans

Purpose To evaluate the diagnostic performance of a 3-dimensional (3D) neuroretinal rim parameter, the minimum distance band (MDB), using optical coherence tomography (OCT) high-density volume scans for open-angle glaucoma. Design…

read more
Get Clinical Tree app for offline access